Siemens SIMATIC and SICAM Products Vulnerable to Trace-File Code Injection and Other Flaws
Vulnerability Disclosure · 2 sources · Updated 5mo ago · First seen Mar 12, 2026

CISA published an ICS advisory warning that multiple Siemens SIMATIC controllers do not properly sanitize the contents of imported trace files, enabling code injection if an attacker can socially engineer a legitimate user into importing a specially crafted trace file. The affected product set includes a broad range of SIMATIC devices, including SIMATIC Drive Controller CPU 1504D/1507D TF, multiple SIMATIC ET 200SP CPU variants (including fail-safe models), and SIMATIC S7-1500 CPUs, among others.
CERT-FR also issued an advisory covering multiple vulnerabilities in Siemens products, listing impacts that include remote code execution, denial of service, and indirect code injection (XSS), and enumerating overlapping affected systems such as the same SIMATIC Drive Controller and SIMATIC ET 200SP families. CERT-FR explicitly references CVE-2025-40943 for several of these SIMATIC devices and additionally notes other Siemens components (e.g., SICAM SIAPP SDK versions prior to 2.1.7), indicating the Siemens security updates/mitigations span more than one product line and vulnerability class beyond the trace-file injection issue highlighted by CISA.
Why it matters
Impact assessment
Multiple Siemens industrial control system product lines are affected, primarily SIMATIC PLCs/controllers and related engineering or simulation components used in manufacturing, energy, utilities, and other OT-heavy environments. The most immediate risk is integrity and operational impact: successful exploitation can enable code injection, remote code execution, denial of service, and data integrity compromise on systems that often support industrial processes.
The exposure is broad across Siemens SIMATIC Drive Controller, ET 200SP, S7-1500, S7-1500 Software Controller, S7-PLCSIM Advanced, SIPLUS variants, and SICAM SIAPP SDK. No confirmed in-the-wild exploitation is stated in the provided references, but the affected footprint is large and includes many "all versions" or pre-fixed versions, making this a meaningful exposure investigation priority for organizations running Siemens OT.
Supporting facts
- Vendor: Siemens.
- Affected families include SIMATIC Drive Controller CPU 1504D TF and 1507D TF.
- Affected families include SIMATIC ET 200SP CPU 1510SP, 1512SP, 1514SP, and Open Controller 1515SP PC/PC2/PC3 variants.
- Affected families include SIMATIC S7-1500 CPU lines, including standard, fail-safe, redundant, technology, pro, and software controller variants.
- Affected products also include SIMATIC S7-1500 Software Controller Linux, S7-PLCSIM Advanced, multiple SIPLUS variants, and SICAM SIAPP SDK prior to 2.1.7.
- Reported impacts across the Siemens advisories include code injection, remote code execution, denial of service, data integrity impact, and indirect code injection/XSS.
- Product status for the listed SIMATIC devices is "known_affected."
- The references do not report confirmed exploitation in the wild.