Multiple Critical Vulnerabilities Disclosed in Industrial Control Systems by CISA

Vulnerability Disclosure · 11 sources · Updated 5mo ago · First seen Oct 16, 2025

Multiple Critical Vulnerabilities Disclosed in Industrial Control Systems by CISA

CISA released thirteen advisories detailing critical vulnerabilities affecting a range of industrial control system (ICS) products from major vendors including Rockwell Automation, Siemens, Hitachi Energy, Schneider Electric, and Delta Electronics. The advisories highlight severe security flaws such as missing authentication for critical functions, improper authorization, buffer overflows, SQL injection, and improper certificate validation. For Siemens TeleControl Server Basic, a vulnerability (CVE-2025-40765) allows unauthenticated remote attackers to obtain password hashes and perform authenticated operations on the database service, with a CVSS v3.1 score of 9.8, indicating critical risk. Rockwell Automation's FactoryTalk View Machine Edition and PanelView Plus 7 are susceptible to path traversal and improper authorization, potentially granting attackers unauthorized access to device file systems and sensitive diagnostic information. FactoryTalk ViewPoint is vulnerable to XML external entity injection, which could result in denial-of-service conditions. Siemens SiPass Integrated faces multiple issues, including buffer overflows and cross-site scripting, which could enable arbitrary code execution and unauthorized access. The Siemens SIMATIC ET 200SP Communication Processors have a missing authentication flaw that could allow attackers to access configuration data remotely. Siemens SINEC NMS is affected by a SQL injection vulnerability that could let low-privileged users escalate privileges. Siemens Solid Edge products are exposed to out-of-bounds read and write vulnerabilities, risking application crashes or code execution. Siemens HyperLynx and Industrial Edge App Publisher are vulnerable to type confusion, potentially leading to arbitrary code execution via crafted HTML pages. Hitachi Energy MACH GWS products have incorrect default permissions and improper validation issues, which could allow attackers to tamper with system files, cause denial of service, or perform man-in-the-middle attacks. The advisories provide technical details, affected product versions, and recommended mitigations, urging administrators to review and apply patches or workarounds. The vulnerabilities impact critical infrastructure sectors such as manufacturing, energy, water, and transportation, with products deployed worldwide. Many of the flaws are remotely exploitable with low attack complexity, increasing the urgency for remediation. CISA emphasizes the importance of timely action to prevent exploitation, as several vulnerabilities could lead to unauthorized access, data manipulation, or disruption of essential services. The advisories also reference the need to consult vendor-specific security updates for the most current information. Organizations are advised to assess their exposure, prioritize patching, and implement recommended security controls to mitigate these risks. The coordinated disclosure underscores the ongoing threat to ICS environments and the necessity for robust security practices across operational technology networks.

Why it matters

Impact assessment

CISA disclosed a broad set of high-severity ICS vulnerabilities across major OT vendors, creating immediate exposure for organizations running affected products in manufacturing, energy, water, transportation, commercial facilities, and other critical infrastructure environments. The most serious issues enable unauthenticated or low-privileged attackers to gain unauthorized access, delete files, extract password hashes, escalate privileges, or potentially execute code, creating risk of operational disruption, safety impact, data manipulation, and reputational damage.

The exposure is widespread rather than narrowly targeted because the affected Siemens, Rockwell Automation, Hitachi Energy, Schneider Electric, and Delta Electronics products are deployed globally across industrial environments. Based on the provided references, CISA reported no known public exploitation for the specifically detailed Siemens SiPass Integrated, Siemens HyperLynx/Industrial Edge App Publisher, Siemens SINEC NMS, and Rockwell Automation FactoryTalk/PanelView issues at publication time, but multiple flaws are remotely exploitable with low attack complexity and warrant urgent remediation.

Affected entities and sectors

  • Vendors named: Rockwell Automation, Siemens, Hitachi Energy, Schneider Electric, Delta Electronics
  • Products named: FactoryTalk View Machine Edition, PanelView Plus 7, FactoryTalk Linx, FactoryTalk ViewPoint, ArmorStart AOP, Solid Edge, SiPass Integrated, SIMATIC ET 200SP Communication Processors, SINEC NMS, TeleControl Server Basic, HyperLynx, Industrial Edge App Publisher, MACH GWS, EcoStruxure, CNCSoft-G2 DOPSoft
  • Sectors explicitly referenced: Critical Manufacturing, Commercial Facilities
  • Story-level sectors referenced: manufacturing, energy, water, transportation
  • Deployment scope: worldwide/global deployment cited for multiple Siemens products

Severity and business consequences

  • Unauthorized access to ICS/OT systems and sensitive files
  • Potential arbitrary code execution on management or server components
  • File deletion on operator interface devices
  • Password recovery/hash theft leading to account compromise
  • Privilege escalation from low-privileged accounts
  • Denial of service and application crashes
  • Potential tampering with configuration data and system files
  • Potential man-in-the-middle exposure from certificate validation weaknesses

Exploitation status

  • No known public exploitation reported in the cited advisories for:
    • Siemens SiPass Integrated
    • Siemens HyperLynx / Industrial Edge App Publisher
    • Siemens SINEC NMS
    • Rockwell Automation FactoryTalk View ME / PanelView Plus 7
Do you run this?See affected versions and whether adversaries are exploiting it.
Check your exposure
Event timeline

How this story unfolded

Events from the most recent confirmed update back to the earliest known activity.

7 events · Oct 14, 2025 – Oct 16, 2025
  1. Oct 16, 20251y ago

    CISA discloses Siemens SINEC NMS SQL injection vulnerability

    CISA advisory ICSA-25-289-08 disclosed CVE-2025-40755, an SQL injection flaw in Siemens SINEC NMS versions prior to V4.0 SP1 that could allow a low-privileged authenticated attacker to escalate privileges. Siemens recommended upgrading to V4.0 SP1 or later, and CISA reported no known public exploitation at publication.

  2. Oct 16, 20251y ago

    Siemens discloses HyperLynx and Industrial Edge App Publisher flaw

    CISA advisory ICSA-25-289-10 disclosed CVE-2025-6554, a type confusion vulnerability affecting Siemens HyperLynx and Industrial Edge App Publisher. Siemens released a patch for Industrial Edge App Publisher version 1.23.5 or later, while no fix was available for HyperLynx at the time of publication.

  3. Oct 16, 20251y ago

    Siemens releases SiPass integrated V3.0 to fix four vulnerabilities

    CISA advisory ICSA-25-289-06 disclosed four vulnerabilities in Siemens SiPass integrated versions prior to V3.0, including buffer overflow, stored XSS, broken access control, and recoverable password storage issues. Siemens said V3.0 or later addresses the flaws, and CISA noted no known public exploitation and that the issues were not remotely exploitable.

  4. Oct 16, 20251y ago

    Rockwell patches FactoryTalk View ME and PanelView Plus 7 flaws

    CISA advisory ICSA-25-289-01 detailed two vulnerabilities, CVE-2025-9064 and CVE-2025-9063, in Rockwell Automation FactoryTalk View Machine Edition and PanelView Plus 7. Rockwell released patches and mitigation guidance, and CISA said no public exploitation was known at publication.

  5. Oct 16, 20251y ago

    CISA issues advisory for Siemens TeleControl Server Basic

    CISA published ICS advisory ICSA-25-289-09 for Siemens TeleControl Server Basic, corresponding to the previously disclosed CVE-2025-40765 information disclosure issue. The advisory formally notified defenders and ICS operators of the affected product and associated risk.

  6. Oct 16, 20251y ago

    CISA publishes 13 ICS advisories including Siemens and Rockwell issues

    CISA released thirteen Industrial Control Systems advisories covering vulnerabilities and security issues across products from Siemens, Rockwell Automation, Hitachi Energy, Schneider Electric, and Delta Electronics. The advisories provided technical details and mitigation guidance for affected OT and ICS environments.

  7. Oct 14, 20251y ago

    CVE-2025-40765 for Siemens TeleControl Server Basic is disclosed

    A high-severity information disclosure vulnerability, CVE-2025-40765, affecting Siemens TeleControl Server Basic was publicly listed. The reference indicates public disclosure of the CVE before broader CISA advisory coverage.

Mallory platform

See the full picture, correlated to your attack surface.

This page covers what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which threat actors are using it right now, and what to deploy next.

Exposure mappingMap indicators from this story to your assets and identify affected systems in minutes.
Threat actor evidenceEvery observed campaign, victim, and pivot linked to actors named in this story.
Associated malwareMalware, exploits, and IOCs connected to the activity described here.
Detection signaturesYARA, Sigma, and Snort rules deployed to your SIEM as soon as they’re published.
Scheduled alertsGet matching new stories delivered to your team as they break, not the next morning.
AI threadsAsk questions about this story and take action on the answers.