Multiple Industrial Control System Vulnerabilities Disclosed by CISA

Vulnerability Disclosure · 6 sources · Updated 5mo ago · First seen Dec 19, 2025

Multiple Industrial Control System Vulnerabilities Disclosed by CISA

CISA released a coordinated set of advisories detailing critical vulnerabilities affecting a range of industrial control system (ICS) products from major vendors, including Inductive Automation, Schneider Electric, Mitsubishi Electric, Siemens, Rockwell Automation, and Axis Communications. The vulnerabilities span a variety of attack vectors, such as improper privilege management, deserialization of untrusted data, OS command injection, and flaws in network protocol implementations. Exploitation of these vulnerabilities could result in severe outcomes, including SYSTEM-level code execution, denial-of-service conditions, information tampering, information disclosure, authentication bypass, and remote code execution across affected ICS platforms.

Vendors have issued patches and mitigation guidance for impacted products, urging organizations in critical infrastructure sectors to update their systems promptly. The advisories highlight the global deployment of these products in sectors such as manufacturing, energy, and commercial facilities, underscoring the potential for widespread impact if left unaddressed. CISA encourages administrators to review the technical details and apply recommended remediations to reduce the risk of exploitation and maintain operational resilience.

Why it matters

Impact assessment

CISA disclosed multiple ICS vulnerabilities across widely deployed products from Inductive Automation, Schneider Electric, Mitsubishi Electric, Siemens, and Rockwell Automation, with exposure concentrated in manufacturing, energy, commercial facilities, and other critical infrastructure environments. Impact ranges from remote code execution with SYSTEM privileges to controller denial of service, information tampering, disclosure, and operational interruption; the Schneider Electric and Siemens issues present the highest enterprise risk because they can be triggered remotely and affect globally deployed industrial platforms.

Affected organizations and environments

  • Critical infrastructure operators using:
    • Inductive Automation Ignition SCADA 8.1.x and 8.3.x
    • Schneider Electric EcoStruxure Foxboro DCS Advisor using Microsoft WSUS
    • Mitsubishi Electric Iconics Digital Solutions GENESIS64, ICONICS Suite, MobileHMI, and MC Works64
    • Siemens products using the Interniche IP-Stack, including SIDOOR, SIMATIC, SIPLUS, SIMOCODE, SINUMERIK, and SIWAREX families
    • Rockwell Automation Micro820, Micro850, and Micro870 controllers
  • Sectors explicitly cited: manufacturing, energy, information technology, and commercial/industrial facilities.

Severity and business effect

  • Schneider Electric CVE-2025-59287 enables potential remote code execution with system-level privileges and carries CVSS 9.8.
  • Inductive Automation CVE-2025-13911 enables SYSTEM-level code execution on Windows hosts, but requires authenticated administrator access and high attack complexity.
  • Siemens CVE-2025-40820 can disrupt TCP-based services through spoofed packet injection, creating denial-of-service risk for industrial communications.
  • Rockwell Automation CVE-2025-13823 and CVE-2025-13824 can force controllers into unresponsive or fault states, including conditions requiring a power cycle.
  • Mitsubishi Electric CVE-2025-11774 can lead to arbitrary code execution, denial of service, information tampering, and disclosure, but requires local access.

Scope and exploitation status

  • Scope is broad because the affected products are deployed worldwide across industrial environments.
  • No public exploitation was reported to CISA for the vulnerabilities covered in the referenced advisories as of 2025-12-18.
  • Despite no confirmed in-the-wild exploitation, the combination of critical ICS exposure and available vendor fixes makes this a proactive remediation priority.
Do you run this?See affected versions and whether adversaries are exploiting it.
Check your exposure
Event timeline

How this story unfolded

Events from the most recent confirmed update back to the earliest known activity.

10 events · Dec 18, 2025
  1. Dec 18, 20251y ago

    CISA releases nine ICS advisories across multiple vendors

    CISA announced the release of nine industrial control systems advisories covering products from Inductive Automation, Schneider Electric, National Instruments, Mitsubishi Electric, Siemens, Advantech, Rockwell Automation, and Axis Communications. The agency urged operators to review the advisories and apply recommended mitigations to reduce risk to critical infrastructure.

  2. Dec 18, 20251y ago

    CISA discloses Rockwell Micro800 controller vulnerabilities

    CISA published advisory ICSA-25-352-07 for CVE-2025-13823 and CVE-2025-13824 affecting Rockwell Automation Micro820, Micro850, and Micro870 controllers. The vulnerabilities could be exploited to trigger denial-of-service conditions in widely used industrial controllers.

  3. Dec 18, 20251y ago

    CISA discloses Siemens Interniche IP-Stack vulnerability

    CISA published advisory ICSA-25-352-05 covering CVE-2025-40820 in Siemens products using the Interniche IP-Stack. The issue stems from improper TCP sequence number validation and could enable denial-of-service attacks against TCP-based services.

  4. Dec 18, 20251y ago

    CISA discloses Mitsubishi Electric Iconics command injection flaw

    CISA published advisory ICSA-25-352-04 for CVE-2025-11774 affecting multiple Mitsubishi Electric Iconics Digital Solutions products. The vulnerability could allow arbitrary code execution, denial of service, tampering, or information disclosure through local configuration-file manipulation.

  5. Dec 18, 20251y ago

    CISA discloses Schneider Electric Foxboro DCS Advisor RCE flaw

    CISA published advisory ICSA-25-352-02 for CVE-2025-59287 affecting Schneider Electric EcoStruxure Foxboro DCS Advisor via WSUS. The critical vulnerability could allow remote code execution with system-level privileges if unpatched.

  6. Dec 18, 20251y ago

    CISA discloses Ignition privilege-escalation vulnerability

    CISA published advisory ICSA-25-352-01 for CVE-2025-13911 in Inductive Automation Ignition 8.1.x and 8.3.x. The flaw allows authenticated administrators to upload malicious project files whose Python scripts execute with SYSTEM privileges on Windows hosts.

  7. Dec 18, 20251y ago

    Siemens releases updates and mitigations for Interniche IP-Stack flaw

    Siemens published fixes for some affected products and workarounds for others in response to CVE-2025-40820 in the Interniche IP-Stack. The vulnerability could let an unauthenticated attacker disrupt TCP connection setup and cause denial of service in numerous Siemens industrial products.

  8. Dec 18, 20251y ago

    Rockwell Automation releases updates for Micro800 controller flaws

    Rockwell Automation released firmware updates and mitigation guidance for CVE-2025-13823 and CVE-2025-13824 affecting Micro820, Micro850, and Micro870 controllers. Successful exploitation could cause denial-of-service conditions that leave controllers unresponsive or in a fault state.

  9. Dec 18, 20251y ago

    Mitsubishi Electric issues fixes for CVE-2025-11774

    Mitsubishi Electric released patches for most affected Iconics Digital Solutions products impacted by CVE-2025-11774, and advised MC Works64 users to upgrade to a fixed product version. The flaw is an OS command injection issue in the keypad function that could enable arbitrary code execution with local access.

  10. Dec 18, 20251y ago

    Microsoft releases WSUS patches for CVE-2025-59287

    Microsoft released security updates KB5070882 and KB5070884 to address CVE-2025-59287, a critical deserialization flaw in Windows Server Update Services used by Schneider Electric EcoStruxure Foxboro DCS Advisor. Schneider Electric later directed customers to apply these patches.

Linked entities

Related entities

Vulnerabilities, threat actors, malware, products, organizations, and breaches Mallory has linked to this story.

Open in app →
Do you run this?See whether adversaries are exploiting this yet, and where the affected versions run in your environment.
Check Your Exposure
Mallory platform

See the full picture, correlated to your attack surface.

This page covers what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which threat actors are using it right now, and what to deploy next.

Exposure mappingMap indicators from this story to your assets and identify affected systems in minutes.
Threat actor evidenceEvery observed campaign, victim, and pivot linked to actors named in this story.
Associated malwareMalware, exploits, and IOCs connected to the activity described here.
Detection signaturesYARA, Sigma, and Snort rules deployed to your SIEM as soon as they’re published.
Scheduled alertsGet matching new stories delivered to your team as they break, not the next morning.
AI threadsAsk questions about this story and take action on the answers.