Skip to main content
Mallory
← Back to News
industrial-control-system-vulnerabilitywidely-deployed-product-advisorycritical-infrastructure-threat

Improper Access Control in Siemens Heliox EV Chargers Enables Unauthorized Service Access via Charging Cable

Vulnerability Disclosure · 2 sources · Updated 5mo ago · First seen Mar 12, 2026

Improper Access Control in Siemens Heliox EV Chargers Enables Unauthorized Service Access via Charging Cable

Siemens Heliox EV chargers were disclosed to contain an improper access control weakness (CWE-923) that could allow an attacker with physical access to the charging interface to reach unauthorized services via the charging cable. CISA published an ICS advisory describing the issue and noting Siemens has released updated software versions; the advisory lists affected models including the Heliox Flex 180 kW EV Charging Station and Heliox Mobile DC 40 kW EV Charging Station, and scores the issue CVSS v3.1 2.6 (Low) with a vector indicating a physical attack requirement (e.g., AV:P). Siemens recommends updating to fixed versions and protecting device/network access per its industrial security operational guidelines.

Canada’s Centre for Cyber Security also highlighted Siemens’ March 2026 advisory set, including updates for Heliox Flex (prior to F4.11.1) and Heliox Mobile DC 40 (prior to L4.10.1), alongside unrelated Siemens product lines (e.g., Mendix, RUGGEDCOM, SIMATIC). A separate Canadian advisory covering Schneider Electric products (EcoStruxure and Modicon lines) is a different vendor’s disclosure and does not pertain to the Siemens Heliox EV charger vulnerability.

Why it matters

Impact assessment

This issue affects organizations operating Siemens Heliox EV charging infrastructure, specifically Heliox Flex 180 kW and Heliox Mobile DC 40 kW chargers deployed worldwide. The direct impact is limited by the required physical access to the charging interface and the low CVSS score, but successful abuse could expose unauthorized internal services on charger systems and create localized operational and security risk.

Summary

The exposure is primarily relevant to EV charging operators, industrial operators, and critical manufacturing environments using affected Siemens chargers. Severity is low from a broad enterprise-risk perspective, but the weakness can matter in unattended or publicly accessible charging environments where physical access is realistic.

Supporting facts

  • Affected vendor: Siemens.
  • Affected product families: Heliox Flex 180 kW EV Charging Station and Heliox Mobile DC 40 kW EV Charging Station.
  • Scope: products are reported as deployed worldwide.
  • Sector noted in the advisory: Critical Manufacturing.
  • Exploitation requirement: attacker needs physical access via the charging cable/interface.
  • Potential outcome: unauthorized access to services reachable through the charging cable.
  • Known exploitation in the wild: not reported in the provided references.
  • Business impact: localized unauthorized service exposure, possible maintenance/service-plane misuse, and potential operational disruption if charger access controls are bypassed in field deployments.
Do you run this?See affected versions and whether adversaries are exploiting it.
Check your exposure
Event timeline

How this story unfolded

Events from the most recent confirmed update back to the earliest known activity.

2 events · Mar 10, 2026 – Mar 12, 2026
  1. Mar 12, 20269mo ago

    CISA republishes Siemens advisory on Heliox EV charger flaw

    On 2026-03-12, CISA republished Siemens ProductCERT advisory SSA-126399 describing an improper access control vulnerability in Siemens Heliox Flex 180 kW and Heliox Mobile DC 40 kW EV charging stations. The advisory said the flaw could allow access to unauthorized services via the charging cable and noted Siemens had released updated versions.

  2. Mar 10, 20269mo ago

    Siemens publishes advisories for multiple product vulnerabilities

    On 2026-03-10, Siemens published security advisories covering vulnerabilities in multiple products, including Heliox EV charging stations, Mendix Applications, RUGGEDCOM APE1808 deployments using Fortigate NGFW, SIDIS Prime, SICAM SIAPP SDK, and SIMATIC S7-1500. Siemens advised users to review the advisories, apply mitigations, and install necessary updates.

Linked entities

Related entities

Vulnerabilities, threat actors, malware, products, organizations, and breaches Mallory has linked to this story.

Open in app →

Organizations

1 linked
Siemens
Do you run this?See whether adversaries are exploiting this yet, and where the affected versions run in your environment.
Check Your Exposure
Mallory platform

See the full picture, correlated to your attack surface.

This page covers what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which threat actors are using it right now, and what to deploy next.

Exposure mappingMap indicators from this story to your assets and identify affected systems in minutes.
Threat actor evidenceEvery observed campaign, victim, and pivot linked to actors named in this story.
Associated malwareMalware, exploits, and IOCs connected to the activity described here.
Detection signaturesYARA, Sigma, and Snort rules deployed to your SIEM as soon as they’re published.
Scheduled alertsGet matching new stories delivered to your team as they break, not the next morning.
AI threadsAsk questions about this story and take action on the answers.