CVE-2025-40831: Report Generation Denial of Service in Siemens SINEC Security Monitor
- Vendor
- Siemens
Siemens SINEC Security Monitor versions before V4.10.0 lack input validation for a date parameter in report generation. An authenticated, low-privileged attacker can exploit this flaw over the network to cause a denial-of-service condition affecting reporting functionality. The vulnerability has a CVSS v3.1 base score of 6.5 with vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation can render report functionality unavailable. No confidentiality or integrity impact is identified; the documented availability impact concerns reporting rather than a confirmed outage of the entire application.
Mitigation
If you can’t patch tonight, do this now.
No vulnerability-specific workaround is identified. Reduce exposure by restricting network access to the application, isolating control system networks behind firewalls and from business networks, and avoiding direct internet exposure. Use maintained VPNs where remote access is necessary, and configure the environment according to Siemens Industrial Security operational guidelines and product manuals.
Remediation
Patch, then assume compromise.
Upgrade Siemens SINEC Security Monitor to V4.10.0 or later, which addresses the vulnerability.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
Frequently asked questions
- Is CVE-2025-40831 exploited in the wild?
- As of Oct 25, 2026, Mallory has no reports of CVE-2025-40831 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2025-40831?
- As of Oct 25, 2026, Mallory has found no public exploit for CVE-2025-40831.
- Is there a patch for CVE-2025-40831?
- Upgrade Siemens SINEC Security Monitor to V4.10.0 or later, which addresses the vulnerability.
- What products are affected by CVE-2025-40831?
- Siemens Sinec Security Monitor.
- How severe is CVE-2025-40831?
- CVE-2025-40831 has a CVSS v4 score of 7.1 (High) and an EPSS score of 0.56% (40th percentile) as of Oct 25, 2026.
Recent activity
6 sources tracked across advisories and community write-ups. News coverage will land here when it surfaces.
No news coverage yet. Advisories and community discussion only.