Skip to main content
Mallory
HighVulnerability

CVE-2025-40830: Arbitrary File Read and Write in Siemens SINEC Security Monitor

Published Dec 9, 2025 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS8.4High · v4
EPSS0.20%6th percentile
CISA KEVNoNot listed
In the wildNoneNo exploitation reported
Vendor
Siemens
IdentifiersCVE-2025-40830CWE-285 · Improper Authorization

Siemens SINEC Security Monitor versions before V4.10.0 lack proper authorization checks in the file_transfer feature of the ssmctl-client command. An authenticated local attacker can use this feature to read or write arbitrary files on a server or sensor, bypassing intended file-access restrictions.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation compromises confidentiality and integrity by allowing unauthorized disclosure and modification of arbitrary files on the affected server or sensor. Modification of operationally important files could also disrupt services. Code execution or privilege escalation is not explicitly established.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to the file-transfer feature and limit local access to trusted users where feasible. Follow Siemens Industrial Security operational guidelines, protect device network access, and isolate control system networks behind firewalls. Network isolation is defense in depth and does not eliminate this authenticated local vulnerability. No vendor-provided vulnerability-specific workaround is identified.

Remediation

Patch, then assume compromise.

Update Siemens SINEC Security Monitor to V4.10.0 or later, which addresses the authorization vulnerability.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
SiemensSinec Security Monitorapplication
FAQ

Frequently asked questions

Is CVE-2025-40830 exploited in the wild?
As of Oct 25, 2026, Mallory has no reports of CVE-2025-40830 being exploited in the wild. It is not listed in CISA KEV.
Is there a public exploit for CVE-2025-40830?
As of Oct 25, 2026, Mallory has found no public exploit for CVE-2025-40830.
Is there a patch for CVE-2025-40830?
Update Siemens SINEC Security Monitor to V4.10.0 or later, which addresses the authorization vulnerability.
What products are affected by CVE-2025-40830?
Siemens Sinec Security Monitor.
How severe is CVE-2025-40830?
CVE-2025-40830 has a CVSS v4 score of 8.4 (High) and an EPSS score of 0.20% (6th percentile) as of Oct 25, 2026.
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity4Community discussion across Reddit, Mastodon, and other social sources.