CVE-2020-8260: Authenticated RCE in Pulse Connect Secure via Uncontrolled Gzip Extraction
- Vendor
- Ivanti
CVE-2020-8260 is an authenticated remote code execution vulnerability in the administrative web interface of Pulse Connect Secure versions before 9.1R9. Uncontrolled extraction of attacker-supplied gzip archives permits arbitrary file placement that can lead to execution of attacker-controlled code on the appliance. Exploitation requires authenticated administrative access. The vulnerability has been exploited in the wild.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation compromises appliance integrity and enables arbitrary code execution, potentially exposing sensitive configuration and credentials. Attackers can use the resulting access to install webshells and establish persistent access. Campaigns exploiting this vulnerability alongside other Pulse Connect Secure flaws deployed malware supporting credential harvesting, authentication bypass, and persistence through software updates; those capabilities are post-exploitation effects rather than inherent authentication-bypass properties of CVE-2020-8260.
Mitigation
If you can’t patch tonight, do this now.
Disable administrative access from external interfaces and restrict management access to trusted administrative systems through network segmentation and firewall rules. Use the Pulse Secure Integrity Checker Tool to identify unauthorized modifications, centralize logs, and monitor unusual administrative authentication and web activity. These measures reduce exposure or support detection but do not replace the security update.
Remediation
Patch, then assume compromise.
Upgrade Pulse Connect Secure to version 9.1R9 or later, applying the fix documented in advisory SA44601. For suspected compromise, preserve forensic evidence and run the Pulse Secure Integrity Checker Tool, accounting for its limitations when examining previously installed software versions. Confirmed compromise requires appliance recovery according to vendor guidance, credential resets for potentially exposed accounts, and investigation of the broader network. Patching alone does not remove existing implants or invalidate stolen credentials.
Exploits
1 exploit validated by Mallory's analysis.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2020-8260 exploited in the wild?
- Yes. As of Nov 26, 2026, Mallory has reports of exploitation in the wild, and CISA added it to KEV on Nov 3, 2021.
- Is there a public exploit for CVE-2020-8260?
- Yes. Mallory tracks 1 public exploit or proof of concept for CVE-2020-8260, the earliest disclosed Oct 26, 2020.
- Is there a patch for CVE-2020-8260?
- Upgrade Pulse Connect Secure to version 9.1R9 or later, applying the fix documented in advisory SA44601. For suspected compromise, preserve forensic evidence and run the Pulse Secure Integrity Checker Tool, accounting for its limitations when examining previously installed software versions.
- What products are affected by CVE-2020-8260?
- Ivanti Connect Secure.
- How severe is CVE-2020-8260?
- CVE-2020-8260 has a CVSS v3.1 score of 7.2 (High) and an EPSS score of 96.5% (100th percentile) as of Nov 26, 2026.
Recent activity
14 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.