CVE-2017-0144: EternalBlue: Microsoft Windows SMBv1 Remote Code Execution
- Vendors
- SiemensMicrosoft Corporation
CVE-2017-0144 is a remote code execution vulnerability in the Microsoft Windows SMBv1 server caused by improper handling of specially crafted requests. An unauthenticated remote attacker can exploit the vulnerability by sending crafted SMBv1 packets to an affected system. Affected releases include Windows Vista SP2; Windows 7 SP1; Windows 8.1 and RT 8.1; Windows 10 initial release, 1511, and 1607; Windows Server 2008 SP2 and 2008 R2 SP1; Windows Server 2012 and 2012 R2; and Windows Server 2016, including applicable Server Core installations. The vulnerability is exploited by EternalBlue and was used by WannaCry and NotPetya for network propagation. Microsoft addressed it in security bulletin MS17-010, released on March 14, 2017.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation permits unauthenticated remote code execution and can compromise system confidentiality, integrity, and availability. Attackers can deploy malware, access or modify data, and use the compromised host to attack other reachable systems. Worm-based exploitation enables rapid propagation across networks containing vulnerable SMBv1 servers. Observed downstream consequences include ransomware deployment, destructive malware execution, data loss, and significant operational disruption. Affected medical systems may also suffer disruption to clinical imaging and related services.
Mitigation
If you can’t patch tonight, do this now.
Disable SMBv1 wherever operationally feasible, using SMBv2 or SMBv3 after compatibility testing. Block Internet-originated SMB connections and restrict TCP ports 445 and 139 to necessary trusted communications. Segment or isolate unpatchable systems and prevent unnecessary workstation-to-workstation SMB access. For medical devices, coordinate isolation or standalone operation with the vendor and clinical stakeholders to avoid jeopardizing patient safety. Monitor for EternalBlue exploitation and unexpected SMB scanning, and immediately isolate compromised hosts. Maintain tested offline backups to reduce downstream ransomware and destructive-malware impact; backups do not prevent exploitation.
Remediation
Patch, then assume compromise.
Apply the operating-system-specific MS17-010 security update or a superseding update. Original updates include KB4012598 for Windows Vista SP2 and Server 2008 SP2; KB4012212 or KB4012215 for Windows 7 SP1 and Server 2008 R2 SP1; KB4012213 or KB4012216 for Windows 8.1 and Server 2012 R2; KB4012214 or KB4012217 for Server 2012; KB4012216 for Windows RT 8.1; KB4012606 for the initial Windows 10 release; KB4013198 for Windows 10 1511; and KB4013429 for Windows 10 1607 and Server 2016. Verify patch installation across all affected hosts. For embedded clinical systems, obtain and apply product-approved fixes through the vendor: Siemens Healthineers provides product-specific updates through customer support, while Philips IntelliSpace Portal deployments require vendor-tested patches and installation-specific guidance.
Exploits
6 exploits validated by Mallory's analysis. Hidden: 30 rejected by Mallory's analysis as not a working exploit; 7 not yet analyzed, such as Exploit-DB entries.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2017-0144 exploited in the wild?
- Yes. As of Nov 26, 2026, Mallory has reports of exploitation in the wild, and CISA added it to KEV on Feb 10, 2022.
- Is there a public exploit for CVE-2017-0144?
- Yes. Mallory tracks 6 public exploits or proofs of concept for CVE-2017-0144, the earliest disclosed Mar 14, 2017.
- Is there a patch for CVE-2017-0144?
- Apply the operating-system-specific MS17-010 security update or a superseding update. Original updates include KB4012598 for Windows Vista SP2 and Server 2008 SP2; KB4012212 or KB4012215 for Windows 7 SP1 and Server 2008 R2 SP1; KB4012213 or KB4012216 for Windows 8.1 and Server 2012 R2; KB4012214 or KB4012217 for Server 2012; KB4012216 for Windows RT 8.1; KB4012606 for the initial Windows 10 release; KB4013198 for Windows 10 1511; and KB4013429 for Windows 10 1607 and Server 2016.
- What products are affected by CVE-2017-0144?
- Siemens Acuson P300 Firmware, Siemens Acuson P500 Firmware, Siemens Acuson Sc2000 Firmware, Siemens Acuson X700 Firmware, Microsoft Corporation Server Message Block, and 4 more.
- How severe is CVE-2017-0144?
- CVE-2017-0144 has a CVSS v3.1 score of 8.8 (High) and an EPSS score of 99.2% (100th percentile) as of Nov 26, 2026.
Recent activity
75 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.